The Apollo Onyx Delivery Microcatheter (AOMC) is a DMSO-compatible, single-lumen, end hole catheter designed for the infusion of the Onyx liquid embolic system (LES). The catheter has a semi-rigid proximal shaft and a highly flexible distal shaft to facilitate the advancement of the catheter in the anatomy. The proximal end of the catheter incorporates a standard Luer adapter to facilitate the attachment of accessories. The outer diameter surface of the catheter is hydrophilically coated to increase lubricity. The AOMC is designed to facilitate catheter retrieval in the event the catheter becomes entrapped within the vasculature. The distal section of the catheter incorporates a detachment zone that allows detachment of the distal tip when the force required to extract the catheter exceeds the force to detach the tip. The catheter has two radiopaque marker bands to visualize the position of the catheter and the detach zone area, one proximal to the detach zone and one at the distal end of the catheter.
Published March 13, 2024 · Recall initiated: January 11, 2024
Summary
FDA records medical device Class II recall Z-1252-2024, published March 13, 2024 and initiated January 11, 2024. Recalling firm: Micro Therapeutics, Inc.; Status: Ongoing; Reported quantity: 82 units; Lot: UDI: 00763000311438/ Lot # B510757, B593510, B610689. Class II means possible temporary or medically reversible effects, or a remote probability of serious health consequences.
Status when published: Ongoing — openFDA updates weekly, so this field may not reflect the current status. Always confirm with the official notice.
What's the hazard
European version of microcatheter were distributed within US which contain a different "Indications for Use".
What to do
Voluntary: Firm initiated · Letter
Get an email when a new FDA recall like this is published
Free. We only write when there's a new recall that matches. Unsubscribe in one click.
Recall details
- Manufacturer
- Micro Therapeutics, Inc.
- Distributor
- US Nationwide distribution in the states of AL, AZ, CA, CT, FL, GA, HI, IA, IL, IN, KS, MA, MD, MI, MO, NC, ND, NE, NV, NY, OH, OK, PA, SC, TN, TX, UT, VA, WA, WI.
- Lot
- UDI: 00763000311438/ Lot # B510757, B593510, B610689
- Risk classification
- Class II
- Area (FDA)
- device
- Country
- United States
Related recalls
- FDAPipeline Flex Embolization Device with Shield Technology REF PED2-300-12 UDI-DI code: 00763000448806 heOctober 7, 2026
- FDAPipeline Flex Embolization Device with Shield Technology, 3.00 mm x 12 mm 027 REF PED2-300-12. IntracranialJuly 29, 2026
- FDAPipeline Flex Embolization Device with Shield Technology, 3.00 mm x 20 mm 027 REF PED2-300-20. IntracranialJuly 29, 2026
- FDAMedtronic Pipeline Vantage Embolization Device with Shield Technology, REF: PED3-021-350-16, PED3-021-250-14,March 12, 2025
- FDAInvacare Homecare Series Bed and Invacare G-Series Beds Containing Component Model Numbers: (1) G50 (2) G53March 13, 2024
- FDAThe Apollo Onyx Delivery Microcatheter (AOMC) is a DMSO-compatible, single-lumen, end hole catheter designedMarch 13, 2024
Questions about this recall
Was The Apollo Onyx Delivery Microcatheter (AOMC) is a DMSO-compatible, single-lumen, end hole catheter designed for the infusion of the Onyx liquid embolic system (LES). The catheter has a semi-rigid proximal shaft and a highly flexible distal shaft to facilitate the advancement of the catheter in the anatomy. The proximal end of the catheter incorporates a standard Luer adapter to facilitate the attachment of accessories. The outer diameter surface of the catheter is hydrophilically coated to increase lubricity. The AOMC is designed to facilitate catheter retrieval in the event the catheter becomes entrapped within the vasculature. The distal section of the catheter incorporates a detachment zone that allows detachment of the distal tip when the force required to extract the catheter exceeds the force to detach the tip. The catheter has two radiopaque marker bands to visualize the position of the catheter and the detach zone area, one proximal to the detach zone and one at the distal end of the catheter. recalled?
Yes. FDA published recall Z-1252-2024 on March 13, 2024. Reported hazard: European version of microcatheter were distributed within US which contain a different "Indications for Use".
What should I do if I have this product?
Voluntary: Firm initiated · Letter