FDAFDA · Food and drugs·Recall number Z-2604-2024
PORTEX Bivona Tracheostomy Silicone Tube, labeled as: a) PAED. TRACHEOSTOMY TUBE 2.5MM AIRE-CUF , Product Code/List Number/Item Code 65P025; b) PAED. TRACHEOSTOMY TUBE 3.0MM AIRE-CUF , Product Code/List Number/Item Code 65P030; c) PAED, TRACHEOSTOMY TUBE 3.5mm AIRE-CUF , Product Code/List Number/Item Code 65P035; d) PAED. TRACHEOSTOMY TUBE 4.0MM AIRE-CUF , Product Code/List Number/Item Code 65P040; e) PAED. TRACHEOSTOMY TUBE 4.5MM AIRE-CUF , Product Code/List Number/Item Code 65P045; f) PAED. TRACHEOSTOMY TUBE 5.0MM AIRE-CUF , Product Code/List Number/Item Code 65P050; g) PAED. TRACHEOSTOMY TUBE 5.5MM AIRE-CUF , Product Code/List Number/Item Code 65P055;
Published September 4, 2024 · Recall initiated: May 29, 2024
Status when published: Ongoing — openFDA updates weekly, so this field may not reflect the current status. Always confirm with the official notice.
What's the hazard
Smiths Medical has identified that the securement flange of specific lots of the Bivona Neonatal/Pediatric and Adult Tracheostomy products may tear because of a manufacturing defect.
What to do
Voluntary: Firm initiated · Letter
Recall details
- Manufacturer
- Smiths Medical ASD Inc.
- Distributor
- Worldwide distribution.
- Lot
- a) UDI/DI 15021312005943, Product Code/List Number/Item Code 65P025, Lot Codes: 3897888, 3981971, 4016049, 4334862, 4374393, 4380064, 4393387, 4400619; b) UDI/DI 15021312005950, Product Code/List Number/Item Code 65P030, Lot Codes: 3880701, 3904666, 3923718, 3926981, 3930042, 4171565, 4196257, 4221324, 4331542, 4334863, 4348379, 4374394, 4388089; c) UDI/DI 15021312005967, Product Code/List Number/Item Code 65P035, Lot Codes: 3864229, 3908001, 3920948, 3923722, 3931150, 3942487, 3955807, 4035680, 4056227, 4086031, 4119112, 4142431, 4147993, 4237343, 4331543, 4334864, 4348380, 4348382, 4369540, 4380065, 4395735; d) UDI/DI 15021312005974, Product Code/List Number/Item Code 65P040, Lot Codes: 3853369, 3868319, 3887746, 3904668, 3942471, 3950391, 3952347, 3965907, 4116095, 4145712, 4153617, 4213393, 4237344, 4289465, 4334865, 4348383, 4348384, 4348385, 4374395, 4383591; e) UDI/DI 15021312005981, Product Code/List Number/Item Code 65P045, Lot Codes: 3868312, 3871060, 3904681, 3904682, 3933472, 4080790, 4089308, 4107571, 4131006, 4145718, 4153595, 4161990, 4204801, 4216296, 4292150, 4334866, 4344346, 4348387, 4374396, 4380066, 4400620; f) UDI/DI 15021312005998, Product Code/List Number/Item Code 65P050, Lot Codes: 3868226, 3871030, 3871031, 3911435, 3930040, 3942493, 3955805, 4015525, 4092637, 4110429, 4139011, 4163824, 4179335, 4213394, 4221325, 4289466, 4328204, 4334867, 4351222, 4369532, 4369533, 4380991, 4388090, g) UDI/DI 15021312006001, Product Code/List Number/Item Code 65P055, Lot Codes: 3840082, 3871043, 3871044, 3901291, 3926980, 3942462, 3942463, 3952341, 3959335, 4011352, 4035681, 4056231, 4077094, 4083913, 4100882, 4107599, 4119123, 4134024, 4138988, 4153615, 4159942, 4168155, 4173721, 4180495, 4195801, 4213395, 4218688, 4267837, 4334869, 4344349, 4351229, 4351230, 4353075, 4389862, 4389863, 4400621
- Risk classification
- Class I
- Area (FDA)
- device
- Country
- United States