SERVICE BRAKES, HYDRAULIC:FOUNDATION COMPONENTS:MASTER CYLINDER
Published October 22, 2010 · Recall initiated: October 22, 2010
What's the hazard
HONDA IS RECALLING CERTAIN MODEL YEAR 2005-2007 ODYSSEY AND ACURA RL VEHICLES. BRAKE FLUID CONTAINING POLYMERS IS USED THAT ACTS AS A LUBRICANT FOR CERTAIN BRAKE SYSTEM COMPONENTS. IF REPLACEMENT BRAKE FLUID IS USED THAT DOES NOT CONTAIN SUCH POLYMERS, OR THAT CONTAINS ONLY SMALL AMOUNTS, A PART OF THE RUBBER SEAL LOCATED AT THE REAR OF THE BRAKE MASTER CYLINDER MAY BECOME DRY, AND THE SEAL MAY CURL DURING MOVEMENT OF THE PISTON. IF THIS OCCURS, A SMALL AMOUNT OF BRAKE FLUID COULD SLOWLY LEAK FROM THE SEAL INTO THE BRAKE BOOSTER.
What to do
DEALERS WILL REPLACE THE BRAKE MASTER CYLINDER SEAL FREE OF CHARGE. THE RECALL IS EXPECTED TO BEGIN DURING DECEMBER 2010. OWNERS MAY CONTACT HONDA AT 1-800-999-1009.
Recall details
- Brand
- ACURA
- Model
- RL
- Manufacturer
- Honda (American Honda Motor Co.)
- Lot
- 2005 ACURA RL | 2005 HONDA ODYSSEY | 2006 ACURA RL | 2006 HONDA ODYSSEY | 2007 ACURA RL | 2007 HONDA ODYSSEY
- Risk classification
- V
- Country
- US