Ingenuity Core128 Model # 728323, computed tomography x-ray system

Published August 14, 2019 · Recall initiated: June 24, 2019

Summary

FDA records medical device Class II recall Z-2187-2019, published August 14, 2019 and initiated June 24, 2019. Recalling firm: Philips Medical Systems (Cleveland) Inc; Status: Terminated; Reported quantity: 116; Lot: System Serial Number 6123, 30016, 30023, 300068, 30153, 32000 through 320513, 52023, 52028 336001 through 336038, 336040 through 336051, 336053, 336055 through 336061, 336063 through 336379, 336382 through 336454, 336701 through 336811, 345218, 760014, 21003-05, 320309, 32053, 32060, 336039-1 336143, 336147, 336331, 7175_06. Class II means possible temporary or medically reversible effects, or a remote probability of serious health consequences.

Status when published: Terminated — openFDA updates weekly, so this field may not reflect the current status. Always confirm with the official notice.

What's the hazard

In certain instances when performing a cardiac step and shoot acquisition with phase tolerance selected, images may be labeled as if phase tolerance had been applied when phase tolerance had not been applied

What to do

Voluntary: Firm initiated · Letter

Get an email when a new FDA recall like this is published

Free. We only write when there's a new recall that matches. Unsubscribe in one click.

Recall details

Manufacturer
Philips Medical Systems (Cleveland) Inc
Distributor
Worldwide distribution. US nationwide including Puerto Rico, Canada, Mexico, Algeria, Argentina, Armenia, Australia, Austria, Azerbaijan, Bahamas, Bahrain, Bangladesh, Belarus, Belgium, Bolivia, Bosnia and Herzegovina, Brazil, Bulgaria, Cambodia, Cayman Islands, Chile, China, Colombia, Cote D'Ivoire, Croatia, Cuba, Cyprus, Czech Republic, Denmark, Djibouti, Dominican Republic, Ecuador, Egypt, Estonia, Ethiopia, Finland, France, French Polynesia, Gabon, Georgia, Germany, Ghana, Gibraltar, Greece, Greenland, Guyana, Hong Kong, Hungary, Iceland, India, Indonesia, Iran, Iraq, Ireland, Israel, Italy, Japan, Jordan, Kazakhstan, Kenya, Korea, Republic of, Kuwait, Kyrgyzstan, Lao People's Democratic Republic, Latvia, Lebanon, Libya, Lithuania, Luxembourg, Macedonia, Malawi, Malaysia, Maldives, Mali, Malta, Martinique, Mauritius, Monaco, Mongolia, Morocco, Mozambique, Myanmar, Nepal, Netherlands, New Caledonia, New Zealand, Nicaragua, Nigeria, Norway, Oman, Pakistan, State of Palestine, Panama, Peru, Philippines, Poland, Qatar, Reunion, Romania, Russian Federation, Rwanda, Saudi Arabia, Senegal, Serbia, Singapore, Slovakia, Slovenia, South Africa, Spain, Sri Lanka, Sudan, Sweden, Switzerland, Syrian Arab Republic, Taiwan, Tanzania, Thailand, Timor-Leste, Tunisia, Turkey, Uganda, Ukraine, United Arab Emirates, United Kingdom, Uzbekistan, Venezuela, Viet Nam, and Yemen
Lot
System Serial Number 6123, 30016, 30023, 300068, 30153, 32000 through 320513, 52023, 52028 336001 through 336038, 336040 through 336051, 336053, 336055 through 336061, 336063 through 336379, 336382 through 336454, 336701 through 336811, 345218, 760014, 21003-05, 320309, 32053, 32060, 336039-1 336143, 336147, 336331, 7175_06
Risk classification
Class II
Area (FDA)
device
Country
United States

Related recalls

Questions about this recall

Was Ingenuity Core128 Model # 728323, computed tomography x-ray system recalled?

Yes. FDA published recall Z-2187-2019 on August 14, 2019. Reported hazard: In certain instances when performing a cardiac step and shoot acquisition with phase tolerance selected, images may be labeled as if phase tolerance had been applied when phase tolerance had not been applied

What should I do if I have this product?

Voluntary: Firm initiated · Letter