CPSCCPSC · Productos de consumo·N.º oficial 10295

Whitco Company LP poles 70 feet tall or higher

Publicado el 6 de julio de 2010

Resumen

CPSC registra el retiro 10295, publicado el 6 de julio de 2010. Empresa responsable: Whitco Company LP, of Fort Worth, Texas (which is out of business); Unidades reportadas: More than 2,500.

Qué peligro representa

Collapse

Qué hacer

To reduce the risk of injury, Whitco Co. LP light poles should be inspected by an engineer or a Level II non-destructive testing technician immediately to identify cracking at or near the weld connecting the pole to the base plate flange. A visual examination with the naked eye or with a magnifier will not determine the extent of any cracking. Non-destructive techniques such as magnetic particle inspection, dye penetrant, or ultrasonic inspection techniques are recommended. If any cracking or fracturing is found, immediately have the affected poles repaired or replaced by a qualified professional. A design analysis to assess the stresses placed on the pole is also recommended. CPSC recommends that all outdoor steel stadium light poles be routinely inspected by a professional. As the manufacturer has become bankrupt, individual owners of the poles must arrange for inspection.

Recibe un correo si Whitco LP vuelve a tener un retiro

Gratis. Solo te escribimos cuando hay un retiro nuevo que coincide. Te das de baja con un clic.

Detalles del retiro

Marca
Whitco Company LP, of Fort Worth, Texas (which is out of business)
Fabricante
Whitco Company LP, of Fort Worth, Texas (which is out of business)
Distribuidor
Lighting contractors nationwide from 2000 through 2005.
País
US

Retiros relacionados

Preguntas sobre este retiro

¿Whitco Company LP poles 70 feet tall or higher fue retirado del mercado?

Sí. CPSC publicó el retiro 10295 el 6 de julio de 2010. Peligro reportado: Collapse

¿Qué debo hacer si tengo este producto?

To reduce the risk of injury, Whitco Co. LP light poles should be inspected by an engineer or a Level II non-destructive testing technician immediately to identify cracking at or near the weld connecting the pole to the base plate flange. A visual examination with the naked eye or with a magnifier will not determine the extent of any cracking. Non-destructive techniques such as magnetic particle inspection, dye penetrant, or ultrasonic inspection techniques are recommended. If any cracking or fracturing is found, immediately have the affected poles repaired or replaced by a qualified professional. A design analysis to assess the stresses placed on the pole is also recommended. CPSC recommends that all outdoor steel stadium light poles be routinely inspected by a professional. As the manufacturer has become bankrupt, individual owners of the poles must arrange for inspection.

¿Cómo sé si mi unidad está incluida en el retiro?

Compara los datos de tu producto con los del aviso. Marca: Whitco Company LP, of Fort Worth, Texas (which is out of business).

Ver aviso oficial de CPSC(abre en cpsc.gov)