Volver al buscador
NHTSANHTSA · Vehículos·N.º oficial 10V534000

EQUIPMENT

Publicado el 2 de noviembre de 2010 · Inicio del retiro: 26 de octubre de 2010

Qué peligro representa

GOSHEN COACH IS RECALLING CERTAIN MODEL YEAR 2006-2007 GOSHEN GC II MOTOR HOMES EQUIPPED WITH TRANS AIR TA 73 EVAPORATORS. THE EVAPORATOR UTILIZES A POWER RESISTOR TO REGULATE BLOWER SPEED. SHOULD A SHORT OCCUR IN THE "LOW OR MEDIUM SPEED" CIRCUIT WHILE THE BLOWER IS IN HIGH SPEED, THE SHORT WILL CAUSE THE SUPPLY VOLTAGE TO FEEDBACK THROUGH THE RESISTOR TO GROUND, NOT DRAWING ENOUGH CURRENT TO TRIP THE FUSE.

Qué hacer

GOSHEN COACH IN COOPERATION WITH TRANS AIR WILL INSTALL A THERMAL SHUTDOWN DEVICE IN SERIES WITH THE SPEED RESISTORS. THIS SERVICE WILL BE PERFORMED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON NOVEMBER 4, 2010. OWNERS MAY CONTACT TRANS AIR WARRANTY AND SERVICE CENTER AT 1-800-673-2446.

Detalles del retiro

Marca
GOSHEN
Modelo
GC II
Fabricante
GOSHEN COACH
Lote
2006 GOSHEN GC II | 2007 GOSHEN GC II
Clasificación de riesgo
V
País
US