cobas® 4800 system z480 instrument. Integrates fully automated total nucleic acid isolation directly from secondary sample tubes.
Published May 29, 2013 · Recall initiated: April 1, 2013
Summary
FDA records medical device Class II recall Z-1346-2013, published May 29, 2013 and initiated April 1, 2013. Recalling firm: Roche Molecular Systems, Inc.; Status: Terminated; Reported quantity: 425 instruments; Lot: Material Number 05200881001 - all lot/serial numbers. Class II means possible temporary or medically reversible effects, or a remote probability of serious health consequences.
Status when published: Terminated — openFDA updates weekly, so this field may not reflect the current status. Always confirm with the official notice.
What's the hazard
In rare instances, channel shifted results have been generated with cobas® 4800 assays run on v1.1.1 of the cobas® 4800 system. Raw data review indicates that, in these cases, all signals are shifted by one channel: channel 1 results report as channel 2, channel 2 results report as channel 3, channel 3 results report as channel 4, and channel 4 results report as channel 1. In the reported
What to do
Voluntary: Firm initiated · Letter
Get an email when a new FDA recall like this is published
Free. We only write when there's a new recall that matches. Unsubscribe in one click.
Recall details
- Manufacturer
- Roche Molecular Systems, Inc.
- Distributor
- Nationwide Distribution.
- Lot
- Material Number 05200881001 - all lot/serial numbers.
- Risk classification
- Class II
- Area (FDA)
- device
- Country
- United States
Related recalls
- FDAcobas Liat Analyzer: respiratory virus panel nucleic acid assay system Catalog Number: 07341920190April 21, 2021
- FDANucleic Acid test intended for screening for MRSA/SA. Each kit has 20 tubes. in vitro diagnostic.April 4, 2018
- FDAcobas® Liat® AnalyzerJuly 27, 2016
- FDAcobas® PCR Urine Kit 100 PKT IVD cobas® PCR Female Swab Kit 100 PKT IVD cobas® PCR media 100T IVD cobas® PCRMarch 5, 2014
- FDATD-Synergy. Laboratory Information System.May 29, 2013
- FDAPROGRESSIVE MEDICAL Laparoscopic Electrode PTFE Coated L Hook 33cm. Intended for the cutting of soft tissueMay 29, 2013
Questions about this recall
Was cobas® 4800 system z480 instrument. Integrates fully automated total nucleic acid isolation directly from secondary sample tubes. recalled?
Yes. FDA published recall Z-1346-2013 on May 29, 2013. Reported hazard: In rare instances, channel shifted results have been generated with cobas® 4800 assays run on v1.1.1 of the cobas® 4800 system. Raw data review indicates that, in these cases, all signals are shifted by one channel: channel 1 results report as channel 2, channel 2 results report as channel 3, channel 3 results report as channel 4, and channel 4 results report as channel 1. In the reported
What should I do if I have this product?
Voluntary: Firm initiated · Letter