Volver al buscador
NHTSANHTSA · Vehículos·N.º oficial 10V099000

EQUIPMENT ADAPTIVE/MOBILITY

Publicado el 16 de marzo de 2010 · Inicio del retiro: 16 de marzo de 2010

Qué peligro representa

TRANS TECH HAS NOTIFIED NHTSA ABOUT A DEFECT IN CERTAIN 2009 TRANS TECH SCHOOL BUSES MANUFACTURED BETWEEN MAY 1 AND OCTOBER 31, 2009, EQUIPPED WITH CERTAIN RICON S SERIES AND K SERIES L-MODEL WHEELCHAIR LIFTS. DUE TO A PROBLEM IN THE SOFTWARE THAT CONTROLS THE LIFTS UP FUNCTION, IF THE SWITCH IS RELEASED BEFORE THE FLOOR LEVEL LIMIT SWITCH IS ACTIVATED, THE LIFT MAY CONTINUE ITS UPWARD TRAVEL FOR APPROXIMATELY 1 SECOND BEFORE STOPPING. THE CONTINUED UPWARD TRAVEL MAY OVERRUN THE FLOOR LEVEL CUT OFF POINT.

Qué hacer

TRANSPORTATION COLLABORATIVE, INC. WILL NOTIFY OWNERS AND THE REPAIRS WILL BE PERFORMED BY AUTHORIZED RICON DEALERS FREE OF CHARGE. CURRENTLY RICON IS DEVELOPING A SOFTWARE SOLUTION AND IS NOT AVAILABLE. UNTIL THE SOFTWARE SOLUTION IS AVAILABLE, RICON WILL PROVIDE OWNERS WITH A BULLETIN OUTLINING PROPER WHEELCHAIR LIFT OPERATION AND WILL SHIP OWNERS A DVD-BASED TRAINING AID TO PROMOTE PROPER LIFT OPERATION AT NO COST. THE SAFETY RECALL BEGAN ON MARCH 31, 2010. OWNERS MAY CONTACT RICON AT 1-818-267-3000 OR TCI AT 1-845-988-2333.

Detalles del retiro

Marca
TRANS TECH
Modelo
RONDAK DW5138FRL
Fabricante
Trans Tech Bus
Lote
2009 TRANS TECH RONDAK DW5138FRL | 2009 TRANS TECH DW6158FRL | 2009 TRANS TECH DW8195FRL
Clasificación de riesgo
V
País
US
Ver aviso oficial de NHTSA