Product is distributed by Zimmer (Warsaw, Indiana)/Synvasive Technology, Inc. (El Dorado Hills, CA) & manufactured under Synvasive Technology, Inc. El Dorado Hills, CA Reciprocating saw blade: A sterile surgical saw blade used to resect damaged cartilage and/or bond in an orthopaedic reconstructive procedure such as a total knee replacement.
Publicado el 24 de abril de 2013 · Inicio del retiro: 2 de abril de 2013
Resumen
FDA registra el retiro Z-1115-2013 de dispositivos médicos de Clase II, publicado el 24 de abril de 2013 e iniciado el 2 de abril de 2013. Empresa responsable: Synvasive Technology Inc; Estado: Finalizado; Cantidad reportada: 3442 units per the part numbers listed; Lote: Lots Numbers included in Recall: 1X311,01251,16325,15023,15024,1Y224,23326,0X401,26385,1Y174, 17151,0Y280,17150,22028,28114,19071,23372,23346,23504,23505, 25134,25341,2W223,2X105,26001,2W573,2W574,24348,25304, 25333,26068,26165,27015,27016,29392,PD4647. La Clase II indica posibles consecuencias temporales o médicamente reversibles, o una probabilidad remota de consecuencias graves.
Estado reportado al momento de publicación: Terminated — openFDA actualiza semanalmente y este campo no refleja el estado más reciente. Confirma siempre con la fuente oficial.
Qué peligro representa
Various reciprocating and oscillating saw blades were incorrectly labeled. The labeling errors include: (1) The pouch says oscillating saw blade when it actually contains a reciprocating saw blade; (2) The box bar code date does not match the human readable expiration date; and (3) The label incorrectly states use with Zimmer/Synthes handset and not the Zimmer Universal Power System.
Qué hacer
Voluntary: Firm initiated · Letter
Recibe un correo cuando FDA publique un retiro como este
Gratis. Solo te escribimos cuando hay un retiro nuevo que coincide. Te das de baja con un clic.
Detalles del retiro
- Fabricante
- Synvasive Technology Inc
- Distribuidor
- Worldwide Distribution - USA (nationwide) and countries of: Austria, Australia, Belgium, Czech Republic, Denmark, Finland, France, Germany, Italy, Japan, Netherlands, Norway, Panama, Spain, Sweden, Switzerland, Tunisia, United Kingdom and Yemen.
- Lote
- Lots Numbers included in Recall: 1X311,01251,16325,15023,15024,1Y224,23326,0X401,26385,1Y174, 17151,0Y280,17150,22028,28114,19071,23372,23346,23504,23505, 25134,25341,2W223,2X105,26001,2W573,2W574,24348,25304, 25333,26068,26165,27015,27016,29392,PD4647
- Clasificación de riesgo
- Class II
- Área (FDA)
- device
- País
- United States
Retiros relacionados
- FDAThe Oxford Partial Knee; Oxford Knee Resection Procedure 3 Pack CEMENTED For use with Stryker System 5, System24 de abril de 2013
- FDACoaguChek XS Pro meters (catalog number 05530199160)bar code scanner. Used with the CoagCHEK XS Pro Meters to24 de abril de 2013
- FDAThe GemStar Pump is a small and lightweight, single channel infusion device designed for use in the home, in24 de abril de 2013
- FDAACCU-CHEK Inform II Blood Glucose Monitoring System bar code scanner. Used with the ACCU-CHEK Inform II System24 de abril de 2013
- FDAThe GemStar Pump is a small and lightweight, single channel infusion device designed for use in the home, in24 de abril de 2013
- FDAAlaris PC unit model 8015 with software version 9.12 Product Usage: The Alaris PC unit is the central24 de abril de 2013
Preguntas sobre este retiro
¿Product is distributed by Zimmer (Warsaw, Indiana)/Synvasive Technology, Inc. (El Dorado Hills, CA) & manufactured under Synvasive Technology, Inc. El Dorado Hills, CA Reciprocating saw blade: A sterile surgical saw blade used to resect damaged cartilage and/or bond in an orthopaedic reconstructive procedure such as a total knee replacement. fue retirado del mercado?
Sí. FDA publicó el retiro Z-1115-2013 el 24 de abril de 2013. Peligro reportado: Various reciprocating and oscillating saw blades were incorrectly labeled. The labeling errors include: (1) The pouch says oscillating saw blade when it actually contains a reciprocating saw blade; (2) The box bar code date does not match the human readable expiration date; and (3) The label incorrectly states use with Zimmer/Synthes handset and not the Zimmer Universal Power System.
¿Qué debo hacer si tengo este producto?
Voluntary: Firm initiated · Letter